Service Tasks
○Purpose: Here we study the types of work that a service person should do to 
maintain the product quality.
● Outline
Below is a table showing the work types of a service person 
associated with the laser exposure system.
Click on the item for which you want to see more specific 
details.
| 
 | 
1. Part Replacement
When replacing certain parts, it may be 
necessary to make adjustments using the service mode or to clear a counter. 
Below,
we discuss these parts that require adjustments after replacement as 
well as the adjustment procedures.
■Laser Scanner Unit
When the laser scanner unit is replaced, the 
numerical value indicated on the laser scanner unit label must be entered in the 
service-mode item.
Enter the service mode shown below, and enter the 
numerical value.
 ∙ 
COPIER 
> ADJUST > LASER > LA-DELAY
2. Maintenance 
Service
The following must be replaced, cleaned, or checked on a periodical 
basis by the service person.
Be sure to perform the appropriate work at the indicated 
intervals.
| 
Item | 
Parts name | 
Work | 
Interval | 
Description | 
| 
Periodically replaced parts | 
- | 
- | 
- | 
The laser exposure system does not have parts that must be replaced 
on a periodical basis. | 
| 
Durables | 
- | 
- | 
- | 
The laser exposure system does not have parts that must be replaced 
as a durable parts. | 
| 
Scheduled servicing | 
Dust-proof glass | 
clean | 
Every 120,000 prints | 
Dry wiping or wiping with 
alcohol. | 
3. Troubleshooting
■E100-0000: BD Error
When a BD error occurs, take the following steps: 
1) Check the connector between the laser scanner unit and the DC 
controller. 
2) Replace the laser scanner unit. 
3) Replace the DC controller circuit board. 
■E110-0001, 0002, 0003: Laser Scanner Unit 
Failure
When the laser scanner unit fails, take the following steps: 
1) Check to see if the laser shutter link is operating 
normally. 
2) Check the connector between the laser scanner unit and the DC 
controller. 
3) Replace the laser scanner unit. 
4) 
Replace the DC controller circuit board. 
 
4. Points to Remember during 
Service
■When Handling the Laser Scanner 
Unit
The laser scanner unit cannot be adjusted except by using special 
tools. Hence, you should never take it apart while servicing the unit out in the 
market. 
■Interchangeability of the Laser Scanner Unit
There is no interchangeability between the laser scanner of the 
iR2270/2870 models and the laser scanner of the iR3570/4570 
models.
Because these laser scanners have different numbers 
of pins on the connector with the scanner motor, it is impossible to mount the 
wrong type of laser scanner even if you try. Be sure to count the 
number of pins on the connector when mounting the laser 
scanner.
| 
  | 
 
 
0 Reviews: