Scaling Control To scale (enlarge/reduce) original to read

Scaling Control
a. Overview
This control is performed when original is enlarged/reduced to read.
The scaling control differs between the main scan direction and the sub scan direction.
The scaling control in the main and sub scan directions is as follows.
 
b. Scaling control in the main scan direction
Original reading in the main scan direction is performed with 100% size. The main controller executes scaling at this time.
 
c. Scaling control in the sub scan direction
The scaling control in the sub scan direction differs according to original reading method and scaling factors.
The scaling control in Book mode and ADF mode is shown below.
 
1) Scaling control in BOOK mode
The original reading speed is changed and data processing on the reader controller PCB/main controller PCB is performed according to scaling factors.
e.g.) Reduced to 25%:
  
Original reading speed: 236mm/sec, Reduced to 50% on the reader controller PCB (1/2 thinning out), Reduced to 50% on the main controller PCB (1/2 thinning out)
e.g.) 100% (direct copy):
   
Original reading speed: 236mm/sec
  
Operation
Scaling Factor
25% to  49%
50% to 99%
100% to  400%
Change of original reading speed (mm/sec)
236 to 120
236 to 119
236 to 59
Digital scaling on the reader controller PCB (%)
50
50
100
Digital scaling on the main controller PCB (%)
50
100
100
 
2) Scaling control in ADF mode
The original reading speed is changed and data processing on the reader controller PCB/main controller PCB is performed according to scaling factors.
e.g.) Reduced to 25%:
  
Original reading speed: 236mm/sec, Reduced to 50% on the reader controller PCB (1/2 thinning out), Reduced to 50% on the main controller PCB (1/2 thinning out)
e.g.) Enlarged to 400%:
  
Original reading speed: 118mm/sec, Enlargement (200%; double) process on the main controller PCB
 
Operation
Scaling Factor
25% to 42%
43% to 84%
85% to  170%
171% to  400%
Change of original reading speed (mm/sec)
236 to  168
274 to  140
277 to 139
276 to  118
Digital scaling on the reader controller PCB (%)
50
50
100
100
Digital scaling on the main controller PCB (%)
50
100
100
100

 