Service Tasks
○Purpose: 
Here, we will study the work conducted by the service person to ensure a 
specific level of machine performance. 
●Outline
The following table describes the types of work performed by the 
service person for the printer control system
For a further discussion, click the appropriate 
item.
| 
 | 
1. 
Parts Replacement
If replaced, some parts of the machine calls for adjustment or 
counter initialization using service mode.
Be sure to perform the tasks indicated below 
whenever you have replaced these parts.
■DC Controller PCB
When replacing the DC 
controller PCB, remove the DIMM ROM [1] from the detached DC controller PCB, and 
mount it on the new DC controller PCB.
■Heat discharge fan filter
If you have replaced the fan filter, you will 
have to reset the fan filter life counter so that the count will start 
anew.
Make the following selections in service mode 
to reset the counter:
 COPIER > COUNTER > DRBL-1 > 
OZ-FIL-1
Each life count is kept in memory on the DC 
controller PCB. If you have to replace the DC controller PCB, be sure to enter 
the count that has been read of the previous PCB.
2. 
Maintenance Servicing
The following must be replaced, cleaned, or checked on a periodical 
basis by the service person.
Be sure to perform the appropriate work at the indicated 
intervals.
| 
Item | 
Parts name | 
Work | 
Interval | 
Description | 
| 
Periodically replaced parts | 
- | 
- | 
- | 
The printer control system does not have parts that must be replaced 
on a periodical basis. | 
| 
Durables | 
Heat discharge fan filter | 
Replace | 
100,000 prints |  | 
| 
Scheduled servicing | 
- | 
- | 
- | 
The printer control system does not have parts that must be serviced 
on a periodical 
basis. | 
■E010-0000 (fault in main motor)
If a fault has occurred in the main motor, go through the following 
steps in sequence: 
1) Check the connectors between 
the main motor(M2) and the DC controller.
2) Replace the main 
motor(M2). 
3) Replace the DC controller 
PCB.
■E014-0000 (fault in fixing motor)
If a fault has occurred in the fixing motor, go through the following 
steps in sequence: 
1) Check the connectors between 
the fixing motor(M3) and the DC controller. 
2) Replace the fixing 
motor(M3). 
3) Replace the DC controller 
PCB.
■E805-0000 (fault in fan motor)
If a fault has occurred in the fan motor, go through the following 
steps in sequence: 
1) Check the connectors between 
the fan(FM1, FM2) and the DC controller. 
2) Replace the fan(FM1, 
FM2). 
3) Replace the DC 
controller PCB.
 

 
0 Reviews: